保偏隔离器单级1M FC/APC 1550nm 900um
	 
	高功率隔离器系列产品包括高功率隔离器和高功率准直器。高功率隔离器系列包括直插式、扩束式隔离器、光纤进出隔离器、自由空间隔离器等。1310/1550/1064nm高功率保偏隔离器是直插式隔离器之一,具有低插入损耗、高隔离度、高功率处理能力、高回波损耗、优异的环境稳定性和可靠性等特点,是光纤激光器和仪器仪表应用的理想选择。
	特征
	应用领域
	规格
	
		
			| 
				Type | 
			
				Single Grade | 
			
				Dual Grade | 
		
		
			| 
				Parameter | 
		
		
			| 
				Type | 
			
				P | 
			
				P | 
		
		
			| 
				Parameter | 
		
		
			| 
				Operating Wavelength (nm) | 
			
				1310,1480, 1550 | 
		
		
			| 
				Bandwidth (nm) | 
			
				±20 | 
		
		
			| 
				Peak isolation (dB) | 
			
				42 | 
			
				58 | 
		
		
			| 
				Isolation (at 23℃) (dB) | 
			
				≥28 | 
			
				≥48 | 
		
		
			| 
				Typ. Insertion Loss (at 23℃) | 
			
				0.4 | 
			
				0.5 | 
		
		
			| 
				Insertion Loss (at-5 ~ +70 ℃) | 
			
				≤0.55 | 
			
				≤0.65 | 
		
		
			
				Extinction 
				Ratio (dB) | 
			
				Type B | 
			
				≥20 | 
			
				≥20 | 
		
		
			| 
				(Both of axis working) | 
		
		
			
				Extinction 
				Ratio (dB) | 
			
				Type F | 
			
				≥22 | 
			
				≥22 | 
		
		
			| 
				(Fast axis blocked) | 
		
		
			| 
				Return loss (Input/Output) (dB) | 
			
				≥55 | 
		
		
			| 
				Power handling (mW) | 
			
				≤300 | 
		
		
			| 
				Fiber Type | 
			
				Panda Fiber | 
		
		
			| 
				Operating temperature (℃) | 
			
				-5~+70 | 
		
		
			| 
				Storage temperature (℃) | 
			
				-40 ~ +80 | 
		
		
			| 
				Dimensions (mm) | 
			
				φ5.5×L35 | 
		
		
			| 
				 
					Above specifications are for devices without the connectors. 
			 | 
		
		
			| 
				 
					For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower, and ER will be 2dB lower. 
			 | 
		
		
			| 
				 
					The PM fiber and the connector key are aligned to the slow axis 
			 | 
		
	
	 
	方面
	
	.jpg)
	 
	订单信息
	
		
			| 
				 
					PMIS 
			 | 
			
				 
					Wavelength 
			 | 
			
				 
					Type 
			 | 
			
				 
					Grade 
			 | 
			
				 
					Axis 
					Alignment 
			 | 
			
				 
					Pigtail Type 
			 | 
			
				 
					Fiber 
					Type 
			 | 
			
				 
					Length 
			 | 
			
				 
					Connector 
			 | 
		
		
			| 
				 
					PMIS 
			 | 
			
				 
					1310 
					1480 
					1550 
				
					  
			 | 
			
				 
					S= Single stage 
					D = Dual Stage 
				
					  
				
					  
			 | 
			
				 
					P 
				
					  
				
					  
			 | 
			
				 
					F=Fast Axis blocked 
					B=Both of axis working 
					S=Slow axis working 
				
					  
			 | 
			
				 
					250=250um bare fiber 
					900=900um loose tube 
					3.0=3.0mm loose tube 
					2.0=2.0mm loose tube 
			 | 
			
				 
					5=Panda fiber 
				
					  
				
					  
			 | 
			
				 
					0.8=0.8 
					1= 1m 
					XX=Other 
				
					  
			 | 
			
				 
					NE=None 
					FA=FC/APC 
					FC=FC/UPC 
					SA=SC/APC 
					SC=SC/UPC 
					XX=Other 
			 |